MRC | Criteria | Characteristic |
---|
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
AEBT | TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -19.80 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.4 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 577.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.2 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -4.0 TO 4.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.0/6.0 2ND RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | SPHERICAL |
TEST | TEST DATA DOCUMENT | 81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAR | BODY OUTSIDE DIAMETER | 0.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.260 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 500.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 80.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 40.5 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.0/6.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 5TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | ZERO POWER RESISTANCE | 100.000 OHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -2.0/2.0 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |