CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
0.318 INCHES MINIMUM AND 0.319 INCHES MAXIMUM
AEBZ
SCHEMATIC DIAGRAM DESIGNATOR
NO COMMON OR GROUNDED ELECTRODE(S)
CQJJ
NONDERATED OPERATING TEMP
-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
CQWM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
500.0 DC SINGLE SECTION
CWJK
CASE MATERIAL
PLASTIC
TEST
TEST DATA DOCUMENT
81349-MIL-C-5 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING G
AAQL
BODY STYLE
W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
AARG
RELIABILITY INDICATOR
NOT ESTABLISHED
ABJT
TERMINAL LENGTH
1.000 INCHES MINIMUM
ADAQ
BODY LENGTH
0.625 INCHES NOMINAL
ADAT
BODY WIDTH
0.530 INCHES MAXIMUM
ADAU
BODY HEIGHT
0.185 INCHES NOMINAL
CQBF
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP
10000.0 MEGOHMS
CQBQ
CAPACITANCE VALUE PER SECTION
2000.000 PICOFARADS SINGLE SECTION
CRDN
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS
0.0 TO 70.0 SINGLE SECTION
CRTP
TOLERANCE RANGE PER SECTION
-2.00 TO 2.00 PERCENT SINGLE SECTION
CWPK
INSULATION RESISTANCE AT REFERENCE TEMP
100000.0 MEGOHMS
CWPM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT
0.0010
CWSG
TERMINAL SURFACE TREATMENT
SOLDER
TTQY
TERMINAL TYPE AND QUANTITY
2 UNINSULATED WIRE LEAD