Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-137-0159 (011370159) |
NCB Code | USA (01) |
Manufacturer | Spd Electrical Systems Inc, Siemens Energy And Automation Inc, Lucent Technologies Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
EH2-B050-F2 | spd electrical systems inc | circuitbreaker | RFQ |
EH2-B050-F2 | siemens energy and automation inc | circuitbreaker | RFQ |
G376972-7 | lucent technologies inc | circuitbreaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.203 INCHES MINIMUM AND 0.235 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 5.984 INCHES MINIMUM AND 6.016 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.984 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.109 INCHES MINIMUM AND 5.141 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.164 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.578 INCHES MINIMUM AND 4.610 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.984 INCHES MINIMUM AND 4.016 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL BETWEEN POLE ONE AND TWO |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 15.0 AC AND 0.25 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 240.0 AC AND 250.0 DC |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL AND CONTACT SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 4 COMPRESSION |
Relevant Components for NSN - 5925-01-137-0159, 5925011370159 | ||||
5998-01-628-9128 (5998016289128) | 5950-00-556-2628 (5950005562628) | 5910-00-502-7030 (5910005027030) | 5930-01-200-1187 (5930012001187) | |
5930-00-436-0040 (5930004360040) | 5998-01-022-6777 (5998010226777) | 5999-01-229-2868 (5999012292868) | 5930-00-451-8223 (5930004518223) | |
5980-01-237-3545 (5980012373545) | 5955-00-463-6952 (5955004636952) | 5975-01-438-5116 (5975014385116) | 5998-01-391-1476 (5998013911476) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote