Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-143-2453 (011432453) |
NCB Code | USA (01) |
Manufacturer | Military Specifications, Thales Nederland Bv, Aeronautical And Support Equipment |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
M39019/02-313 | military specifications | circuitbreaker | RFQ |
352250042475 | thales nederland bv | circuitbreaker | RFQ |
MIL-C-39019/2 | military specifications | circuitbreaker | RFQ |
MIL-PRF-39019/2 | military specifications | circuitbreaker | RFQ |
84-32055 PC11 | aeronautical and support equipment | circuitbreaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.625 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.700 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC AND 2.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.100 MAXIMUM AT 800 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF AND HERMETICALLY SEALED |
CRTK | SWITCH TERMINAL TYPE | TAB,SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 0.5 AC AND 0.5 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 50.0 DC |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39019/2 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLEC |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
Relevant Components for NSN - 5925-01-143-2453, 5925011432453 | ||||
5998-01-628-9128 (5998016289128) | 5950-00-556-2628 (5950005562628) | 5910-00-502-7030 (5910005027030) | 5930-01-200-1187 (5930012001187) | |
5930-00-436-0040 (5930004360040) | 5998-01-022-6777 (5998010226777) | 5999-01-229-2868 (5999012292868) | 5930-00-451-8223 (5930004518223) | |
5980-01-237-3545 (5980012373545) | 5955-00-463-6952 (5955004636952) | 5975-01-438-5116 (5975014385116) | 5998-01-391-1476 (5998013911476) | |