MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 3.671 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES MINIMUM FIRST MOUNTING FACILITY AND 2.374 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.700 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.200 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 2 |
AKSL | PURPOSE FOR WHICH DESIGNED | SPECIFIC |
APCN | COIL QUANTITY | 2 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS AND POLARIZED |
CBME | CUBIC MEASURE | 35.241 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 250.0 MILLIAMPERES DC ALL WINDINGS |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 25.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC INDUCTIVE LOAD AND 15.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC MOTOR LOAD AND 20.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC RESISTIVE LOAD AND 20.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 10 SCREW ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27706 GOVERNMENT STANDARD |