Recently Updated NSN 5945-00-754-6611 Or (5945007546611) Part List

Item Name Relay Electromagnetic
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5945 Relays and Solenoids
National Item Identification Number (NIIN) 00-754-6611 (007546611)
NCB Code USA (00)
Manufacturer Drs Power And Control Technologies, Nimikkeistokeskus Ncb Finland, Military Specifications, Labinal Llc, Military Standards Corp
Part Number Manufacturer Item Name RFQ
6042H152 drs power and control technologies relay electromagnetic RFQ
10137972 nimikkeistokeskus ncb finland relay electromagnetic RFQ
MIL-PRF-6106 military specifications relay electromagnetic RFQ
6042H152 labinal llc relay electromagnetic RFQ
MIL-R-6106 military specifications relay electromagnetic RFQ
MS24142-D2 military standards corp relay electromagnetic RFQ

Technical Characteristics of NSN 5945007546611

MRCCriteriaCharacteristic
ABKWOVERALL HEIGHT4.972 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
APCNCOIL QUANTITY1
APNAWINDING DC RESISTANCE RATING52.0 OHMS NOMINAL SINGLE WINDING
APNPDUTY TYPECONTINUOUS
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CBMECUBIC MEASURE60.755 CUBIC INCHES
CQYJMOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY
CSKPNONPILE-UP AUXILIARY CONTACT ARRANGEMENT1 POLE,SINGLE THROW,NORMALLY CLOSED,DOUBLE BREAK,MOMENTARY ACTION AND 1 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE200.0 AMPERES AC RESISTIVE LOAD AND 200.0 AMPERES DC RESISTIVE LOAD
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
TESTTEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN
ABHPOVERALL LENGTH3.640 INCHES MAXIMUM
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMKOVERALL WIDTH3.315 INCHES MAXIMUM
ADTVCASE MATERIALMETAL
ADZCENVIRONMENTAL PROTECTIONHERMETIC
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY
AKDXWINDING QUANTITY1
AKSLPURPOSE FOR WHICH DESIGNEDGENERAL
APNQARC QUENCHING METHODAIR
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CRNGNONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION
CRXHTIME DELAY0.015 SECONDS MAXIMUM FIXED RELEASE TIME
CRXHTIME DELAY0.04 SECONDS MAXIMUM FIXED OPERATE TIME
CSQCAUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 AMPERES DC INDUCTIVE LOAD
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE150.0 AMPERES AC MOTOR LOAD AND 200.0 AMPERES DC MOTOR LOAD
CWGMAUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD
CWGMAUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD
CWGMAUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD
TTQYTERMINAL TYPE AND QUANTITY8 THREADED STUD ALL FUNCTIONS
ZZZKSPECIFICATION/STANDARD DATA96906-MS24142 GOVERNMENT STANDARD

Relevant Components for NSN - 5945-00-754-6611, 5945007546611
5998-01-628-9128 (5998016289128) 5950-00-556-2628 (5950005562628) 5910-00-502-7030 (5910005027030) 5930-01-200-1187 (5930012001187)
5930-00-436-0040 (5930004360040) 5998-01-022-6777 (5998010226777) 5999-01-229-2868 (5999012292868) 5930-00-451-8223 (5930004518223)
5980-01-237-3545 (5980012373545) 5955-00-463-6952 (5955004636952) 5975-01-438-5116 (5975014385116) 5998-01-391-1476 (5998013911476)