MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 3.700 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.576 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.305 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT AND HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 225.0 MILLIAMPERES AC SINGLE WINDING |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.065 SECONDS MAXIMUM FIXED RELEASE TIME |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION AND 1 POLE,SINGLE THROW,NORMALLY CLOSED,DOUBLE BREAK,MOMENTARY ACTION |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 124.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC MOTOR LOAD AND 25.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS24143 GOVERNMENT STANDARD |