Item Name | Transformer Pulse |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-028-3725 (010283725) |
NCB Code | USA (01) |
Manufacturer | Espey Mfg And Electronics Corp, Lockheed Martin Corporation, General Electric Company, Air Force Lifecycle Management |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
CR-121-U | espey mfg and electronics corp | transformer pulse | RFQ |
7412922P0001 | lockheed martin corporation | transformer pulse | RFQ |
82H434 | general electric company | transformer pulse | RFQ |
B7412922P1 | general electric company | transformer pulse | RFQ |
7412922P1 | lockheed martin corporation | transformer pulse | RFQ |
8712804 | air force lifecycle management | transformer pulse | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.000 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.221 INCHES NOMINAL SINGLE GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND SECONDARY CENTER TAP SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 4.250 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AFFL | MOUNTING BOLT CIRCLE DIAMETER | 5.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 41.4 AMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 9.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.61 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.59 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 97.75 AC VOLTS MINIMUM SINGLE COMPONENT 2ND PRIMARY AND 132.25 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 3 SOLDER STUD AND 4 WIRE LOOP |
Relevant Components for NSN - 5950-01-028-3725, 5950010283725 | ||||
5998-01-628-9128 (5998016289128) | 5950-00-556-2628 (5950005562628) | 5910-00-502-7030 (5910005027030) | 5930-01-200-1187 (5930012001187) | |
5930-00-436-0040 (5930004360040) | 5998-01-022-6777 (5998010226777) | 5999-01-229-2868 (5999012292868) | 5930-00-451-8223 (5930004518223) | |
5980-01-237-3545 (5980012373545) | 5955-00-463-6952 (5955004636952) | 5975-01-438-5116 (5975014385116) | 5998-01-391-1476 (5998013911476) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote