MRC | Criteria | Characteristic |
---|
AHSF | FLANGE QUANTITY | 2 |
AHSY | FLANGE INSIDE HEIGHT | 0.617 INCHES MINIMUM FIRST FLANGE AND 0.623 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 1.250 INCHES MINIMUM FIRST FLANGE AND 1.256 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.610 INCHES MINIMUM SECOND FLANGE AND 0.640 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.164 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.174 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.12 |
CQGM | MAXIMUM OPERATING PRESSURE | 25.0 POUNDS PER SQUARE INCH GAGE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
AHRW | TUBING TWIST TYPE | TWISTABLE SINGLE TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM SECOND FLANGE AND 1.126 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.415 INCHES MINIMUM FIRST FLANGE AND 0.445 INCHES MAXIMUM FIRST FLANGE |
AHTX | INSERTION LOSS IN DECIBELS | 0.10 |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 7.440 INCHES NOMINAL |
CTCJ | FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
CWBG | WAVEGUIDE OFFSET DISTANCE | 1.560 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | BEND TYPE |
AHRX | TUBING TWIST ANGLE IN DEG | 90.0 SINGLE TUBING SEGMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM SECOND FLANGE AND 0.501 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
SFTT | SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
SUPP | SUPPLEMENTARY FEATURES | FREQUENCY 8.49 TO 9.61 GHZ |