MRC | Criteria | Characteristic |
---|
AHSZ | FLANGE OUTSIDE WIDTH | 2.480 INCHES MINIMUM FIRST FLANGE AND 2.520 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.171 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.20 |
CQGM | MAXIMUM OPERATING PRESSURE | 15.0 POUNDS PER SQUARE INCH GAGE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
SFTT | SURFACE TREATMENT | CHROMATE ALL FLANGE OUTSIDE SURFACES AND CADMIUM ALL FLANGE OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT INSIDE SURFACES |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHRW | TUBING TWIST TYPE | TWISTABLE SINGLE TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM SECOND FLANGE AND 1.256 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 20.000 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | FREQUENCY RANGE 8.5 TO 9.6 GHZ |
PMLC | PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.628 INCHES MINIMUM SECOND FLANGE AND 0.631 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.730 INCHES MINIMUM FIRST FLANGE AND 1.770 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.480 INCHES MINIMUM FIRST FLANGE AND 0.520 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTX | INSERTION LOSS IN DECIBELS | 0.20 |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CONTACT TYPE FIRST FLANGE |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY ALL FLANGE |
PRMT | PRECIOUS MATERIAL | SILVER |
AHSF | FLANGE QUANTITY | 2 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |