Request a Competitive Quote for Part Number CF2-G3-U-10-240-60-1 with NSN 5925008892470 by Eaton Corporation!

Part Number: CF2-G3-U-10-240-60-1
Alternate P/N: CF2G3U10240601
Manufacturer: Eaton Corporation
NIIN: 008892470
Item Name : Circuit Breaker
CAGE Code: 74193
FSG: 59 Electrical and Electronic Equipment Components
Country: USA
NCB Code: 00

Thank you for taking an interest in the top-caliber NSN products we feature here on AI NSN Parts. On this page, you can submit a quote request for part number CF2-G3-U-10-240-60-1, a Circuit Breaker item that is manufactured by Eaton Corporation. Listed alongside the NSN 5925008892470 within our database, part number CF2-G3-U-10-240-60-1 is conveniently ready for purchase at any time.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Customer Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Note : We Will Not Share Your Information To Any Third Parties.

Upload RFQ SHEET

To ensure listings like part number CF2-G3-U-10-240-60-1 are ready for swift installation, we have a rigorous quality assurance program in place. As such, we make it easy for you to inquire about popular NSNs like 5925-00-889-2470, as well as the many other Eaton Corporation products produced under CAGE Code 74193 that interest you. For the benefit of our customers, we carefully vet every entity that we source from, guaranteeing that you only receive superior-caliber offerings in every order. With these dedications, you can always purchase from us with confidence. Furthermore, we also organize our stock based on Federal Supply Classes, so you can find popular items under FSCs like 5925 Circuit Breakers. Do not hesitate to submit the RFQ form below, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. Get started today and see why so many customers steadily depend on AI NSN Parts for their operational needs.

NSN Information for Part Number CF2-G3-U-10-240-60-1 with NSN 5925-00-889-2470, 5925008892470

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-889-2470

Item PartTypeName:

CIRCUIT BREAKER

59250088924700P
CIICHCCESDPMICCriticalityENAC
UA
Part NumberISCRNVCRNCCHCCMSDSSADC
34651-121CA

Characteristics Data of NSN 5925-00-889-2470, 5925008892470

MRCCriteriaCharacteristic
ADAQBODY LENGTH5.844 INCHES NOMINAL
ADAUBODY HEIGHT2.609 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.546 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.032 INCHES NOMINAL
AKPXPOLE QUANTITY2
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT28.000 MINIMUM AT 200 PCT AND 110.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY4 SCREW
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABTDMOUNTING SLOT WIDTH0.164 INCHES NOMINAL
ADATBODY WIDTH2.064 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.032 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.218 INCHES NOMINAL
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE AND 4 SLOT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS480.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC