Thank you for taking an interest in the top-caliber NSN products we feature here on AI NSN Parts. On this page, you can submit a quote request for part number AM333HEMG6-30-250-16-400, a Circuit Breaker item that is manufactured by Eaton Corporation. Listed alongside the NSN 5925010693439 within our database, part number AM333HEMG6-30-250-16-400 is conveniently ready for purchase at any time.
To ensure listings like part number AM333HEMG6-30-250-16-400 are ready for swift installation, we have a rigorous quality assurance program in place. As such, we make it easy for you to inquire about popular NSNs like 5925-01-069-3439, as well as the many other Eaton Corporation products produced under CAGE Code 74193 that interest you. For the benefit of our customers, we carefully vet every entity that we source from, guaranteeing that you only receive superior-caliber offerings in every order. With these dedications, you can always purchase from us with confidence. Furthermore, we also organize our stock based on Federal Supply Classes, so you can find popular items under FSCs like 5925 Circuit Breakers. Do not hesitate to submit the RFQ form below, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. Get started today and see why so many customers steadily depend on AI NSN Parts for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-069-3439 Item Description: CIRCUIT BREAKER | 5925 | 010693439 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM333HEMG6-30-250-16-400 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
THSD | Thread Series Designator | UNC |
AKPX | Pole Quantity | 3 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 12.750 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRP | Ultimate Trip Time Per Pole In Seconds | 0.600 MINIMUM ALL LOCATIONS AND 2.000 MAXIMUM ALL LOCATIONS |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADTV | Case Material | METAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.539 INCHES MINIMUM AND 2.683 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQSM | Switch Location And Position Designation | EXTERNAL AT POLE ONE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.020 MINIMUM AT 500 PCT ALL LOCATIONS AND 0.070 MAXIMUM AT 500 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | TURRET |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.