Thank you for taking an interest in the top-caliber NSN products we feature here on AI NSN Parts. On this page, you can submit a quote request for part number AM3333HEMG6-3-250-4-50, a Circuit Breaker item that is manufactured by Eaton Corporation. Listed alongside the NSN 5925010706244 within our database, part number AM3333HEMG6-3-250-4-50 is conveniently ready for purchase at any time.
To ensure listings like part number AM3333HEMG6-3-250-4-50 are ready for swift installation, we have a rigorous quality assurance program in place. As such, we make it easy for you to inquire about popular NSNs like 5925-01-070-6244, as well as the many other Eaton Corporation products produced under CAGE Code 74193 that interest you. For the benefit of our customers, we carefully vet every entity that we source from, guaranteeing that you only receive superior-caliber offerings in every order. With these dedications, you can always purchase from us with confidence. Furthermore, we also organize our stock based on Federal Supply Classes, so you can find popular items under FSCs like 5925 Circuit Breakers. Do not hesitate to submit the RFQ form below, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. Get started today and see why so many customers steadily depend on AI NSN Parts for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-070-6244 Item Description: CIRCUIT BREAKER | 5925 | 010706244 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM3333HEMG6-3-250-4-50 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 4 |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND 1.0 DC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
PKWT | Unpackaged Unit Weight | 12.750 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
CQSM | Switch Location And Position Designation | EXTERNAL AT POLE ONE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT EACH POLE |
ADAT | Body Width | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
CBBL | Features Provided | SLIDING BAR INTERLOCK |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | UNC |
AJWX | Mounting Surface To Terminal End Distance | 1.492 INCHES MINIMUM AND 2.331 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 8 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | TURRET |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND HERMETICALLY SEALED |