Thank you for taking an interest in the top-caliber NSN products we feature here on AI NSN Parts. On this page, you can submit a quote request for part number WE2555, a Transformer Power item that is manufactured by Magnetika Inc. Listed alongside the NSN 5950003483801 within our database, part number WE2555 is conveniently ready for purchase at any time.
To ensure listings like part number WE2555 are ready for swift installation, we have a rigorous quality assurance program in place. As such, we make it easy for you to inquire about popular NSNs like 5950-00-348-3801, as well as the many other Magnetika Inc products produced under CAGE Code 15634 that interest you. For the benefit of our customers, we carefully vet every entity that we source from, guaranteeing that you only receive superior-caliber offerings in every order. With these dedications, you can always purchase from us with confidence. Furthermore, we also organize our stock based on Federal Supply Classes, so you can find popular items under FSCs like 5950 Coils and Transformers. Do not hesitate to submit the RFQ form below, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. Get started today and see why so many customers steadily depend on AI NSN Parts for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-348-3801 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003483801 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
WE2555 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.530 INCHES MAXIMUM3.530 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.448 INCHES MAXIMUM ALL MOUNTING FACI |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.010 INCHES MAXIMUM ALL MOUNTING FACI |
ABMK | OVERALL WIDTH | 2.580 INCHES MINIMUM AND 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM2.680 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM 2ND GROUP AND 0.148 INCHES MINIMUM 2ND GROUP AND 0.165 INCHES MAXIMUM 2ND GROUP0.165 INCHES MAXIMUM 2ND GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-WYE |
ADAU | BODY HEIGHT | 1.420 INCHES MAXIMUM1.420 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS4 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPTHREADED HOLE 1ST GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPUNTHREADED HOLE 2ND GROUPUNTHREADED HOLE 2ND GROUPTHREADED HOLE 1ST GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP0.138 INCHES 1ST GROUP |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 230.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC VOLTS NOM |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | VOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARYVOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARY |
TEST | TEST DATA DOCUMENT | 07187-4010238 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD |