Thank you for taking an interest in the top-caliber NSN products we feature here on AI NSN Parts. On this page, you can submit a quote request for part number FCA410DY9, a Relay Electromagnetic item that is manufactured by Struthers Dunn Inc. Listed alongside the NSN 5945013634192 within our database, part number FCA410DY9 is conveniently ready for purchase at any time.
To ensure listings like part number FCA410DY9 are ready for swift installation, we have a rigorous quality assurance program in place. As such, we make it easy for you to inquire about popular NSNs like 5945-01-363-4192, as well as the many other Struthers Dunn Inc products produced under CAGE Code 78290 that interest you. For the benefit of our customers, we carefully vet every entity that we source from, guaranteeing that you only receive superior-caliber offerings in every order. With these dedications, you can always purchase from us with confidence. Furthermore, we also organize our stock based on Federal Supply Classes, so you can find popular items under FSCs like 5945 Relays and Solenoids. Do not hesitate to submit the RFQ form below, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. Get started today and see why so many customers steadily depend on AI NSN Parts for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-363-4192 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013634192 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
FCA410DY9 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.000 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SECOND MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SECOND MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SECOND MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
ABHP | OVERALL LENGTH | 1.718 INCHES MINIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SECOND MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.937 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SECOND MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.